Combustion and explosion characteristics of dust

Minimum ignition temperature of dust layers

MIT-L is the lowest temperature at which a dust layer in an accumulated state can ignite. It is primarily used for the selection of explosion-proof electrical equipment and the control of hot surface

MIT-L is the lowest temperature at which a dust layer in an accumulated state can ignite. It is primarily used for the selection of explosion-proof electrical equipment and the control of hot surface temperatures of heating devices.

GB/T 16430-2018 Determination of the minimum ignition temperature of dust layer

GB/T 3836.12-2019 Explosive atmospheres-Part 12: Material characteristics for combustible dusts-Test methods

ASTM E2021-2015 Standard Test Method for Hot-Surface Ignition Temperature of Dust Layers

ISO/IEC 80079-20-2-2016 Explosive atmospheres-Part 20-2: Material characteristics-Combustible dusts test methods